KE200

KE200

MICNO

15 THÁNG

Input voltage 3AC 220V±15% 3AC 380V±15% Input frequency 47~63Hz Output Output voltage 0~Rated voltage Output frequency 0~400Hz


 

Input Input voltage

3AC 220V±15%   3AC 380V±15%

Input frequency

47~63Hz

   
 
Output Output voltage

0~Rated voltage

Output frequency

0~400Hz

   
 

Control

Feature

Control mode

V/f control (with/without PG), Sensorless vector control, Close loop vector control

Operation command mode

Digital setting, analog setting, serial communication setting, multi-step speed setting, PID setting, etc. These frequency settings can be combinated & switched in various modes.

Overload capacity

150% 60s, 180% 10s, 200% 3s.

Starting torque

0Hz/150% (VC); 1Hz/150% (SVC)

Speed adjustment range

1:1000 (VC); 1:100 (SVC)

Speed control precision

±0.2% (SVC); ±0.02% (VC)

Speed response

<20ms (SVC); <3.5ms (VC)

Torque limit

Available (parameter setting 4 modes)

Torque response

20Hz (SVC); 40Hz (VC)

Frequency control range

0.1~400Hz

Frequency accuracy

Digital command: ±0.01% (-10℃~40℃)
Analog command: ±0.1% (25℃±10℃)

Setting frequency resolution

Digital keypad command: ±0.01Hz

Output frequency resolution

Analog command: ±0.03Hz/60Hz (11bit + code) 0.01Hz

Frequency setting signal

-10V~10V, 0~10V (20kΩ), 4~20mA

ACC/DEC mode

0.01s~6000.0s (ACC time and DEC time are set separately, four kinds of ACC/DEC time)

Braking torque

20% (150% when equipped with braking resistor)

V/f curve

15 fixed types and random V/f curve setting

   
 
Protection Function Motor overload protection

Protect by hot electric 

Instantaneous over voltage

Motor coast to stop when the inverter outputs 200% rated current

Blown fuse protection

Motor coast to stop

Overload

Motor coast to stop when the inverter outputs 150% rated current for 1 minute (150% 2 minutes can be customized)

Over voltage

Stop when main circuit voltage>410V(820V)*1

Under voltage

Stop when main circuit voltage<190V(380V)*1

Instantaneous power off compensation

Set the motor stops in 2 sec when power off in the running motor, then the motor runs continuously

Radiator overheat 

Protect by temperature switch

Stall protection

ACC and DEC, stall protection when running

Ground fault

Protect by circuit

Charging protection

No display if DC voltage of main circuit below 50V

   
 
Terminals Input terminals

DI: 8 on-off inputs (2 fixed)
3 AI: 2 programmable. AI1: voltage 0~10V
A12: voltage -10~10V or current 4~20mA

Output terminals

2 programmable open collector output
1 relay output (normally open)
1 programmable relay output
2 programmable analog output: -10~10V

Communication terminal*2

Offer RS485 communication interface, support MODBUS-RTU communication protocol 

   
 

Enviorment

Limit

Ambient temperature

-10℃~40℃, derated 4% when the temperature rise by each1℃ (40℃~50 ℃). 

Humidity

90%RH or less (non-condensing)

Altitude

≤1000M: output rated power, >1000M: output derated

Storage temperature

-20℃~60℃

Storage atmosphere

Indoor, without direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip, salt, vibration, etc. 

 

Sản phẩm cùng loại

KE300-0R7G-T4 Call

KE300-0R7G-T4

Vui lòng gọi
KE300 Call

KE300

Vui lòng gọi
KE300-2R2G-T4 Call

KE300-2R2G-T4

Vui lòng gọi
KE300-011G/015P-T4 Call

KE300-011G/015P-T4

Vui lòng gọi
KE300-030G/037P-T4 Call

KE300-030G/037P-T4

Vui lòng gọi
KE300-037G/045P-T4 Call

KE300-037G/045P-T4

Vui lòng gọi
KE300X-0R4G-S2 Call

KE300X-0R4G-S2

Vui lòng gọi
K550 Call

K550

Vui lòng gọi
KE300-018G/022P-T4 Call

KE300-018G/022P-T4

Vui lòng gọi
KE300-055G/075P-T4 Call

KE300-055G/075P-T4

Vui lòng gọi
E380 Call

E380

Vui lòng gọi

Top

   (0)